Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Acta Ortop Bras ; 30(spe2): e246988, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36506856

RESUMO

Objectives: Our purpose was to evaluate the clinical results of PCL tibial avulsion fracture fixation performed with 4 mm cancellous screws using a dual posteromedial (PM) portal technique. Methods: In a prospective study, we followed 12 patients submitted to PCL tibial insertion avulsion arthroscopic fixation using dual PM portals with cancellous screws from March 2014 to Jan 2020. The proximal higher PM portal served as an instrument portal and provided an optimal trajectory for arthroscopic screw fixation of larger PCL avulsion fractures. The lower PM portal was used as a viewing portal. Results: Significant improvements were found between the preoperative and postoperative mean Lysholm scores at six months. The preoperative IKDC score mean of 10.13 increased to 89.3 at the end of six months. Minor adverse results with this technique were: grade I on posterior sag in five knees (41.6%), temporary stiffness in two cases (16.7 %), delayed union in one patient (8.3 %), and difficulty squatting at the end of six months in one patient (8.3%). Temporary extension lag was present in two individuals (16.7%), and fixed subtle flexion deficit of 3-5 degrees occurred in one individual (8.3 %). Conclusion: The outcomes obtained with the proposed technique were similar to those obtained with open techniques, although mild flexion deficits and discreet posterior sag may be present in a significant number of cases. Level of Evidence II; Prospective Cohort Study .


Objetivos: O objetivo foi avaliar os resultados clínicos da fixação da fratura da avulsão tibial PCL realizada com parafusos esponjosos de 4 mm, utilizando uma técnica de portal postero-medial (PM) duplo. Métodos: Em um estudo prospectivo, acompanhamos 12 pacientes submetidos à fixação da avulsão tibial de inserção PCL por via artroscópica utilizando portais duplos PM com parafusos esponjosos de março de 2014 a janeiro de 2020. O portal PM proximal superior serviu como um portal de instrumentos e forneceu uma trajetória ideal para a fixação artroscópica com parafusos de fixação de fraturas avulsas PCL maiores. O portal PM inferior foi usado como um portal de visualização. Resultados: Foram encontradas melhorias significativas entre o pré-operatório e o pós-operatório, com pontuação média de Lysholm aos seis meses. A pontuação média do IKDC pré-operatório de 10,13 aumentou para 89,3 no final dos seis meses. Os resultados adversos menores com esta técnica foram: grau I na flacidez posterior de cinco joelhos (41,6%), rigidez temporária em dois casos (16,7%), união tardia em um paciente (8,3%) e dificuldade de agachamento ao final de seis meses em um paciente (8,3%). O atraso temporário da extensão estava presente em dois indivíduos (16,7%) e o déficit de flexão sutil fixo de 3-5 graus ocorreu em um indivíduo (8,3%). Conclusão: Os resultados obtidos com a técnica proposta foram similares aos obtidos com técnicas abertas, embora déficits leves de flexão e discreta flacidez posterior possam estar presentes em um número significativo de casos. Nível de Evidência II; Estudo de Coorte Prospectivo.

2.
Acta ortop. bras ; 30(spe2): e246988, 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1403055

RESUMO

ABSTRACT Objectives Our purpose was to evaluate the clinical results of PCL tibial avulsion fracture fixation performed with 4 mm cancellous screws using a dual posteromedial (PM) portal technique. Methods In a prospective study, we followed 12 patients submitted to PCL tibial insertion avulsion arthroscopic fixation using dual PM portals with cancellous screws from March 2014 to Jan 2020. The proximal higher PM portal served as an instrument portal and provided an optimal trajectory for arthroscopic screw fixation of larger PCL avulsion fractures. The lower PM portal was used as a viewing portal. Results Significant improvements were found between the preoperative and postoperative mean Lysholm scores at six months. The preoperative IKDC score mean of 10.13 increased to 89.3 at the end of six months. Minor adverse results with this technique were: grade I on posterior sag in five knees (41.6%), temporary stiffness in two cases (16.7 %), delayed union in one patient (8.3 %), and difficulty squatting at the end of six months in one patient (8.3%). Temporary extension lag was present in two individuals (16.7%), and fixed subtle flexion deficit of 3-5 degrees occurred in one individual (8.3 %). Conclusion The outcomes obtained with the proposed technique were similar to those obtained with open techniques, although mild flexion deficits and discreet posterior sag may be present in a significant number of cases. Level of Evidence II; Prospective Cohort Study.


RESUMO Objetivos O objetivo foi avaliar os resultados clínicos da fixação da fratura da avulsão tibial PCL realizada com parafusos esponjosos de 4 mm, utilizando uma técnica de portal postero-medial (PM) duplo. Métodos Em um estudo prospectivo, acompanhamos 12 pacientes submetidos à fixação da avulsão tibial de inserção PCL por via artroscópica utilizando portais duplos PM com parafusos esponjosos de março de 2014 a janeiro de 2020. O portal PM proximal superior serviu como um portal de instrumentos e forneceu uma trajetória ideal para a fixação artroscópica com parafusos de fixação de fraturas avulsas PCL maiores. O portal PM inferior foi usado como um portal de visualização. Resultados Foram encontradas melhorias significativas entre o pré-operatório e o pós-operatório, com pontuação média de Lysholm aos seis meses. A pontuação média do IKDC pré-operatório de 10,13 aumentou para 89,3 no final dos seis meses. Os resultados adversos menores com esta técnica foram: grau I na flacidez posterior de cinco joelhos (41,6%), rigidez temporária em dois casos (16,7%), união tardia em um paciente (8,3%) e dificuldade de agachamento ao final de seis meses em um paciente (8,3%). O atraso temporário da extensão estava presente em dois indivíduos (16,7%) e o déficit de flexão sutil fixo de 3-5 graus ocorreu em um indivíduo (8,3%). Conclusão Os resultados obtidos com a técnica proposta foram similares aos obtidos com técnicas abertas, embora déficits leves de flexão e discreta flacidez posterior possam estar presentes em um número significativo de casos. Nível de Evidência II; Estudo de Coorte Prospectivo.

3.
Arthrosc Tech ; 10(10): e2229-e2235, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34754728

RESUMO

The posterior cruciate ligament surgery invariably demands adequate posterior compartment visualisation and instrumentation. The addition of posteromedial (PM) portal during posterior cruciate ligament (PCL) surgeries remains essential. The further addition of one more proximal posteromedial (PM) portal further enhances the instrumentation including suture passage in the substance of PCL or screws insertion and more so obviates the need for trans-septal and posterolateral (PL) portals. This additional PM portal is created in the safe zone under direct visualisation utilising outside-in technique and is spaced to prevent crowding of instrument with arthroscope. The proximal higher PM portal serves as instrument portal and provides optimal trajectory for even arthroscopic screw fixation of PCL avulsion fractures.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...